Repair Method - Company Ranking(15 companyies in total)
Last Updated: Aggregation Period:Jul 16, 2025〜Aug 12, 2025
This ranking is based on the number of page views on our site.
Display Company Information
Company Name | Featured Products | ||
---|---|---|---|
Product Image, Product Name, Price Range | overview | Application/Performance example | |
【Applicable Conditions】 ■ Applicable for pipe diameters from φ800mm to φ3,000mm. Note: Equipment can be transported in and out from a manhole with a diameter of φ600mm. ■ Joint spacing of 90mm or less, withstands internal water pressure of 1.5Mpa, and external water pressure of 0.2Mpa (when additional fixed rings are adopted). ■ Step difference of pipe joints is 40mm or less, and difference in internal pipe diameter is 20mm or less. ■ Pipe slope is normally constructed at less than 5 degrees; for slopes greater than this, additional safety measures will be implemented during construction. ■ Applicable pipe types include PC pipes, FRPM pipes, concrete pipes, ductile pipes, steel pipes, polyethylene pipes, etc. *For more details, please refer to the PDF document or feel free to contact us. | [Usage] ■Repair and seismic reinforcement of pipeline joints, etc. *For more details, please refer to the PDF document or feel free to contact us. | ||
【Applicable Conditions (Excerpt)】 ■ Applicable for pipe diameters from φ800mm to φ3,000mm ■ The test is conducted by applying a pressure of 0.5MPa (maximum value) and the pressure drop rate of 80% after holding for 5 minutes is used as the judgment criterion ■ The standard test slope for the pipeline is up to 5%, and for slopes greater than this, separate safety measures will be implemented to allow testing ■ The spacing between pipe joints must be 50mm or less, with a step difference of 20mm or less, and an internal diameter difference of 20mm or less ■ Applicable pipe types include PC pipes, FRPM pipes, concrete pipes, ductile pipes, steel pipes, polyethylene pipes, etc. ■ Testing is possible even with a water depth of about 10 to 20mm inside the pipe, depending on the size of the internal diameter * For more details, please refer to the PDF document or feel free to contact us. | 【Usage】 ■ Air-tightness inspection of pipeline joints, etc. *For more details, please refer to the PDF document or feel free to contact us. | ||
---
--- |
--- |
-
- Featured Products
-
Agricultural Water Conservancy Facility Preservation and Repair Method "Water Stop Band Method"
- overview
- 【Applicable Conditions】 ■ Applicable for pipe diameters from φ800mm to φ3,000mm. Note: Equipment can be transported in and out from a manhole with a diameter of φ600mm. ■ Joint spacing of 90mm or less, withstands internal water pressure of 1.5Mpa, and external water pressure of 0.2Mpa (when additional fixed rings are adopted). ■ Step difference of pipe joints is 40mm or less, and difference in internal pipe diameter is 20mm or less. ■ Pipe slope is normally constructed at less than 5 degrees; for slopes greater than this, additional safety measures will be implemented during construction. ■ Applicable pipe types include PC pipes, FRPM pipes, concrete pipes, ductile pipes, steel pipes, polyethylene pipes, etc. *For more details, please refer to the PDF document or feel free to contact us.
- Application/Performance example
- [Usage] ■Repair and seismic reinforcement of pipeline joints, etc. *For more details, please refer to the PDF document or feel free to contact us.
Agricultural Water Conservancy Facility Maintenance and Repair Method "Test Band Method"
- overview
- 【Applicable Conditions (Excerpt)】 ■ Applicable for pipe diameters from φ800mm to φ3,000mm ■ The test is conducted by applying a pressure of 0.5MPa (maximum value) and the pressure drop rate of 80% after holding for 5 minutes is used as the judgment criterion ■ The standard test slope for the pipeline is up to 5%, and for slopes greater than this, separate safety measures will be implemented to allow testing ■ The spacing between pipe joints must be 50mm or less, with a step difference of 20mm or less, and an internal diameter difference of 20mm or less ■ Applicable pipe types include PC pipes, FRPM pipes, concrete pipes, ductile pipes, steel pipes, polyethylene pipes, etc. ■ Testing is possible even with a water depth of about 10 to 20mm inside the pipe, depending on the size of the internal diameter * For more details, please refer to the PDF document or feel free to contact us.
- Application/Performance example
- 【Usage】 ■ Air-tightness inspection of pipeline joints, etc. *For more details, please refer to the PDF document or feel free to contact us.
-
Membership (free) is required to view all content.
Already a Member? Log In Here